About

The Indiana University Nuclear Magnetic Resonance (NMR) facility provides access to state-of-the-art instrumentation and expertise in solution NMR spectroscopy. The facility has six high resolution NMR spectrometers from 400 MHz to 800 MHz to perform all modern solution-state experiments for structural elucidation, molecular dynamics and reaction kinetic study of small molecules and large biological molecules in solution. The facility also has a 200 MHz NMR spectrometer for undergraduate teaching, and an EPR spectrometers for research.

Chemistry NMR Laboratory – Room C237 in the Chemistry building features Varian 500 MHz and two 400 MHz Inova NMR spectrometers. Staff offices, user workstations, wet lab with hood, sample refrigerator, chemical cabinets and other resources are also located here. Room C234F hosts a Varian 600 MHz Inova NMR spectrometer.

MetaCyt BioNMR Laboratory – This lab located in Simon Hall 037 houses a Varian 800 MHz VNMRS NMR spectrometer and a Bruker 600 MHz Avance Neo NMR spectrometer. It has an 8′ deep pit design with stainless steel platform, climate control, oxygen sensor purge safety system and an enclosed room for water chillers, the magnet pump and magnet monitoring system. A wet lab area is also available.

Undergraduate Teaching Laboratory – Varian 200 MHz Mercury NMR spectrometer in Chemistry, Room 145.

EPR Laboratory – Bruker EMX EPR spectrometer in Chemistry, Room A220.

Varian 800 MHz NMR SystemVarian 800 MHz VNMRS NMR Spectrometer with Pumped AS800 Magnex Magnet and Salt Tolerant HCN Cold Probe. Thanks to Lilly Endowment. Bruker 600 MHz NMR SystemBruker 600 MHz Avance Neo NMR Console with Oxford Shielded Magnet and TCI Cryo Probe with cooled preamps for 1H, 13C, 15N and 2H. NIH Grant.
Varian Inova 600 MHz NMR SystemVarian 600 MHz Inova NMR Spectrometer. 4 Channel with 5mm and 8mm PFG HCN Probes, Waveform Generators and Gradient 2H Shimming. Varian Inova 500 MHz NMR SystemVarian 500 MHz Inova NMR Spectrometer. 3 Channel with PFG Dual, PFG HCX, PFG HCN, PFG Penta and Broadband Probes, Waveform Generators and Gradient 2H Shimming.
Varian Inova 400 MHz NMR SystemVarian 400 MHz Inova NMR Spectrometer. 3 Channel with 4 Nuc PFG, Indirect Detection PFG and Broadband Probes and Gradient 2H Shimming. Varian Inova 400 MHz NMR SystemSecond Varian 400 MHz Inova NMR Spectrometer. 2 Channel with 4 Nuc, Indirect Detection PFG and Broadband Probes and Gradient 2H Shimming.
Varian Mercury 200 MHz NMR SystemVarian 200 MHz Mercury NMR Spectrometer with PFG 4 Nuc Probe and Gradient 2H Shimming. Bruker EMX EPRBruker EMX X-band CW EPR Spectrometer, Low Temp. to 4 K.

Comments are closed.